www..com Level Sensors Amplifier, Conductive Type ELC (Charging), ELD (Discharging) Level control for conductive liquids Max./min. control of charging (ELC) or discharging (ELD) Adjustable sensitivity: 10 - 100 k Output: 5 A SPDT For mounting on DIN-rail in accordance with DIN/EN 50 022 * 22.5 mm housing * LED-indication for relay and power supply ON * AC power supply * * * * * Product Description Level control relay with max./min. control of charging or discharging. The sensitivity is adjustable on absolute scale from 10 to 100 k. When using only the max. level sensor, single level control is possible. Ordering Key Housing Function Type Output Power supply Measuring range ELC C 230 100K Type Selection Mounting For DIN-rail Output SPDT SPDT Type Charge (Filling) Discharge (Emptying) Supply: 24 VAC ELC C 024 100K ELD C 024 100K Supply: 115 VAC ELC C 115 100K ELD C 115 100K Supply: 230 VAC ELC C 230 100K ELD C 230 100K www..com Max. level Min. level 10 - 100 k 3s 20 k (typ. 5 k) 25 VAC/250 A (rms) Input Specifications Input through Y1 & Y2 through Y1 & Y3 Range Reaction time Repeat accuracy Sensor voltage Output Specifications Output Rated insulation voltage Contact ratings (AgCdO) Resistive loads AC 1 DC 1 Small inductive loads AC 15 DC 13 Mechanical life Electrical life Operating frequency SPDT relay 250 VAC (contact/elect.) 5 A/250 VAC 5 A/24 VDC 2 A/250 VAC 3 A/24 VDC 40 x 106 operations 105 operations (at max. load) 7200 operations/h Supply Specifications Power supply Rated operational volt. through term. A1 & A2 024 115 230 Frequency Voltage interruption Dielectric voltage Rated impulse withstand volt. Rated operational power Overvoltage cat. III (IEC 60664) 24 VAC 15% 115 VAC 15% 230 VAC 15% 50/60 Hz, -5/+5 Hz 40 ms 2 kVAC (rms) 4 kV (1.2/50 s) 2.5 VA Specifications are subject to change without notice (25.06.99) 1 www..com www..com 4U DataSheet 4 U .com www..com ELC/ELD General Specifications Power ON delay Accuracy Max. level Min. level Drift Temperature Supply voltage Indication for Power supply ON Output ON Environment Degree of protection Pollution degree Operating temperature Storage temperature Dimensions Weight Approvals CE-marking 3s -20/+50% 50% 1 k/C 0.5%/V LED, green LED, yellow IP 20 3 -20 to +50C (-4 to +122F) -50 to +85C (-58 to +185F) 100x22.5x91.7 mm (LxWxH) 170 g UL, CSA (only ELC-type) Yes Mode of Operation ELC Relay for the control of charging of conductive liquids. The relay operates when the level drops below the min. level sensor. The relay releases if the level rises above the max. level sensor. Single level control is obtained by connecting the max. level sensor only. ELD Relay for the control of discharging of conductive liquids. The relay operates when the level rises above the max. level sensor. The relay releases when the level drops below the min. level sensor. Single level control is obtained by connecting the max. level sensor only. Level Setting Setting of level on absolute scale, 10-100 k. Accessories Conductive level probes: VH, VPC, VPP, VN, VNI, VNY, VNYI, VT, VTI, VS. Wiring Diagrams ELC L ELD www..com k > Max. Min. Y2 Y3 (PE) N Y1 A2 11 (PE) A1 12 14 Max. Min. Y2 Y3 Y1 k < L A1 12 14 A2 11 N Operation Diagrams ELC ELD Y2-Y1 Y2-Y1 Y3-Y1 Y3-Y1 2 Specifications are subject to change without notice (25.06.99) DataSheet 4 U .com www..com www..com 4U |
Price & Availability of ELDC024100K |
|
|
All Rights Reserved © IC-ON-LINE 2003 - 2022 |
[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy] |
Mirror Sites : [www.datasheet.hk]
[www.maxim4u.com] [www.ic-on-line.cn]
[www.ic-on-line.com] [www.ic-on-line.net]
[www.alldatasheet.com.cn]
[www.gdcy.com]
[www.gdcy.net] |